• Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture
  • Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture
  • Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture
  • Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture
  • Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture
  • Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture
  • Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture
  • Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture

Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture

Modular small temperature difference waste heat recovery units transfer heat using temperature differences between media without additional energy consumption, solving issues like clogging, scaling, corrosion and high maintenance costs of traditional heat exchangers, widely used for heat recovery and reuse in aquaculture systems.
$8523.00
Shandong Naxin New Energy Co., Ltd.

Shandong Naxin New Energy Co., Ltd.

View Supplier
Registration Date October 2017
Number of Employees 200
Factory Area 46,000 m²
Annual Sales 400 Million RMB
Main Products Water Source Heat Pump, Air Source Heat Pump, Low Temperature Difference Waste Heat Recovery Unit, Filter, Micro-filter, Protein Separator, Oxygen Increasing Equipment, Disinfection Equipment, Aquaculture Pond, Intelligent Bait Feeder, Fish Manure Collector; Full Life Cycle System Solutions for Modern Agriculture & Aquaculture
Target Markets Aquaculture Industry, Industrial Recirculating Aquaculture System
Details
Specifications
Heat energy is transferred by the temperature difference between two water media. High-temperature water releases heat and cools down, while low-temperature water absorbs heat and warms up. Adopt pure physical heat exchange without medium mixing or secondary pollution, realizing zero energy consumption.
  • Energy Saving & Zero Consumption:Natural heat exchange by temperature difference, no electric power required, greatly reducing operating cost.
  • Anti-blocking & Anti-scaling:Large-flow channel design prevents dirt adhesion, effectively avoiding blockage and scaling.
  • High Corrosion Resistance:Titanium alloy heat exchange tube and PP shell adapt to seawater and brackish water environments.
  • Low Maintenance:Stable structure and low failure rate, suitable for long-term continuous operation.
  • Modular Combination:Multi-stage cascaded structure, flexible assembly and capacity expansion according to actual water flow.

Widely applied in industrial recirculating aquaculture, seawater farming and constant-temperature breeding. It recovers waste heat from tail water to preheat inlet water, stabilize water temperature and reduce the load of heating equipment.
Primary Water Resistance (kPa)
72 / 54 / 72 / 54 / 72
Secondary Water Resistance (kPa)
78 / 58.5 / 78 / 58.5 / 78
Design Pressure (MPa)
0.5
Model
SSHRQ-60/80 / SSHRQ-120 / SSHRQ-160 / SSHRQ-240 / SSHRQ-320
Heat Exchange Process
1×4/1×5 Cascaded / 2×4 Cascaded / 2×5 Cascaded / 4×4 Cascaded / 4×5 Cascaded
Primary Water Flow (m³/h)
20-50 / 30-70 / 40-80 / 60-140 / 80-160
Hydrostatic Test Pressure (MPa)
0.625
Design Temperature (℃)
50
Working Temperature (℃)
≤50
Heat Exchange Tube Material
TA1 Titanium Alloy
Shell Material
PP Polypropylene
Unit Size (mm)
3005×603×1852/2151 / 3005×900×1852 / 3005×900×2151 / 3005×1810×1852 / 3005×1810×2151
  • Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture
  • Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture
  • Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture
  • Modular Small Temperature Difference Waste Heat Recovery Unit for Aquaculture

Description

Heat energy is transferred by the temperature difference between two water media. High-temperature water releases heat and cools down, while low-temperature water absorbs heat and warms up. Adopt pure physical heat exchange without medium mixing or secondary pollution, realizing zero energy consumption.
  • Energy Saving & Zero Consumption:Natural heat exchange by temperature difference, no electric power required, greatly reducing operating cost.
  • Anti-blocking & Anti-scaling:Large-flow channel design prevents dirt adhesion, effectively avoiding blockage and scaling.
  • High Corrosion Resistance:Titanium alloy heat exchange tube and PP shell adapt to seawater and brackish water environments.
  • Low Maintenance:Stable structure and low failure rate, suitable for long-term continuous operation.
  • Modular Combination:Multi-stage cascaded structure, flexible assembly and capacity expansion according to actual water flow.

Widely applied in industrial recirculating aquaculture, seawater farming and constant-temperature breeding. It recovers waste heat from tail water to preheat inlet water, stabilize water temperature and reduce the load of heating equipment.